RE: [Fwd: common fluid velocities] [bayes][bcc][faked-from][mx][spf]

From: <Bruce>
Date: Wed Nov 16 2005 - 12:32:00 EST


Do you mean something as simple as Crane Technical Paper No. 410, "Flow of Fluids Through Valve, Fittings, and Pipe, page 3-6:

Reasonable Velocities for the Flow of Water through Pipe

Boiler feed................... 8 - 15 feet per minute
Pump suction and drain lines.. 4 - 7 fpm
General service .............. 4 - 10 fpm
City ......................... Up to 7 fpm

??

                            ... Bruce D. Bullough ...
                            Sebesta Blomberg & Associates, Inc.
                            2381 Rosegate
                            Roseville, MN  55113          USA
                            desk: 651-634-7344   fax: 651-634-7400
                            www.sebesta.com


-----Original Message-----
From: <a href="/group/PipingDesign/post?postID=I9BPiChb_pITfS844xzugcWc8XyoxmcFbOpc64jS_WaqlEjHdCXnoZZp3a2SmRi0fa1xv61q68aq1-UhYB6IypbyZL7qc3E">PipingDesign@yahoogroups.com</a> [mailto:<a href="/group/PipingDesign/post?postID=I9BPiChb_pITfS844xzugcWc8XyoxmcFbOpc64jS_WaqlEjHdCXnoZZp3a2SmRi0fa1xv61q68aq1-UhYB6IypbyZL7qc3E">PipingDesign@yahoogroups.com</a>] On Behalf Of Paul Bowers
Sent: Wednesday, November 16, 2005 10:51 AM To: <a href="/group/PipingDesign/post?postID=I9BPiChb_pITfS844xzugcWc8XyoxmcFbOpc64jS_WaqlEjHdCXnoZZp3a2SmRi0fa1xv61q68aq1-UhYB6IypbyZL7qc3E">PipingDesign@yahoogroups.com</a> Subject: [PipingDesign] [Fwd: common fluid velocities] [bayes][bcc][faked-from][mx][spf]

Hello,

I'm looking for a chart that shows common fluid velocities for piping system design (commercial design). Can you help me with this at all?