NDE Options for 700 Deg. F

From: <Ken>
Date: Thu Mar 16 2006 - 14:26:00 EST

I want to have a nondestructive evaluation for surface cracks performed in carbon steel fittings at a service temperature of 650 - 700 Deg. F. I understand that use of liquid penetrant or magnetic particle methods would require a shutdown.

A local inspection firm is investigating use of high temperature probes for eddy current method.

Are there other NDE methods to consider for this application? Are there any personal experiences with trying to accomplish this type of evaluation?

Ken A. Nisly-Nagele, P.E.

Project Engineer, Mechanical

Applied Engineering Services, Inc.

7999 Knue Road

Indianapolis, IN 46250

317-585-8920

[Non-text portions of this message have been removed] Received on Thu Mar 16 14:26:00 2006