> Why is that the B31.3 formula for blanks not be used for a flat plate
> welded
> to the end of a pipe. Is it because the end connections are not same
> in the
> 2 cases?

The method of connection between the shell and the flay plate affects the stress in the plate. You can see how the design differs from Figure UG-34 in Section VIII div 1. With a bolted connection the edge moment induced by the bolt load has to be considered. Christopher Wright P.E. |"They couldn't hit an elephant at chrisw@skypoint.com | this distance" (last words of Gen.