On Dec 13, 2006, at 7:43 PM, Satria, Utama wrote:
> I'm aware that GDE based on ASME VIII, but it's only for its pressure
> design. It's bandlock is not a requirement of
> ASME VIII. I'll keep you posted if I can find it.
Technically, the Div 1 compliance requirement is U-2(g). There is no
prescribed Code detail for such a device, and in that case the designer
must comply with U-2(g) and satisfy the AI with the design package.
That's a pretty neat idea for a closure. Christopher Wright P.E. |"They couldn't hit an elephant at chrisw@skypoint.com | this distance" (last words of Gen.
.......................................| John Sedgwick, Spotsylvania1864)