Re: Double Locking Trap Closure (i.e GD Engineering Bandlock 2)

From: <Christopher>
Date: Wed Dec 13 2006 - 21:43:00 EST

On Dec 13, 2006, at 7:43 PM, Satria, Utama wrote:

> I'm aware that GDE based on ASME VIII, but it's only for its pressure
> design. It's bandlock is not a requirement of
> ASME VIII. I'll keep you posted if I can find it.
Technically, the Div 1 compliance requirement is U-2(g). There is no prescribed Code detail for such a device, and in that case the designer must comply with U-2(g) and satisfy the AI with the design package.

That's a pretty neat idea for a closure. Christopher Wright P.E. |"They couldn't hit an elephant at chrisw@skypoint.com | this distance" (last words of Gen.

.......................................| John Sedgwick, Spotsylvania
1864)
http://www.skypoint.com/~chrisw/ Received on Wed Dec 13 21:43:00 2006

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:12 EDT