Re: minimum pipe spool length

From: <shivakumar>
Date: Sat Jan 06 2007 - 02:51:00 EST

Yes, as you rightly said One NPS is the normal pracitice. If your pipe size is large, you can go for smaller spool piece. However, under extreme conditions, the lenght of spool piece shall be more than 3T in order to avoid the overlap of HAZs of adjacent weld joints.

Hope this give you an additional idea for desiding minimum length of spool piece.

Thanks

Shivakumar Angadi
Design Engineer
Joint Operations - Kuwait Gulf Oil Company & Chevron Texaco
--- dd jdh <saduemk@yahoo.co.in> wrote:

> hi all,
>
> May anyone tell what will be the minimum possible
> pipe spool length
> for a butt welded end connection.
>
> As per AWS the minimum pipe spool length required
> in a line is one
> NPS.
>
> where site condition restricts this minimum
> requirement, is it
> possible to adopt
>
> lesser length spools.
>
> thanks and regards,
>
> Sadanandan.M.K
>
> PE middle east
>
> Send free SMS to your Friends on Mobile from your
> Yahoo! Messenger. Download Now!
> http://messenger.yahoo.com/download.php
>
> [Non-text portions of this message have been
> removed]
>
>



Do You Yahoo!?
Tired of spam? Yahoo! Mail has the best spam protection around http://mail.yahoo.com Received on Sat Jan 06 02:51:00 2007