Answer: Maximum allaowable working pressure (MAWP).
MAWP may be => design pressure
Depending on design code and the test medium, the test pressute = 1.1 x MAWP, or 1.25 x MAWP, or 1.25 x MAWP, or 1.3 x MAWP, or 1.5 x MAWP;
Regards,
Dhayanithi V <pipingworld@gmail.com> wrote:
for pipe wall thickness calculation, which pressure we have to take
into
account like *operating*, *design*,*test* pressure
[Non-text portions of this message have been removed]