Re: regarding wall thick calculation

From: <Christopher>
Date: Wed Jul 25 2007 - 16:30:00 EDT

On Jul 25, 2007, at 3:10 PM, Alok Dubey wrote:

> That`s fine! What I am asking which code says that design pressure
> shall be 1.5 times of operating pressure? I understand that test
> pressure should be of D.P. Recent edition of BPV has even brought
> this lower to 1.3.

You're getting things confused again. No code says any such thing. And test pressure is not a design condition. Test pressures are a consequence of the maximum allowable working pressure (MAWP). If you want to talk about this stuff you really should use correct terminology. Otherwise everyone just gets confused.

Christopher Wright P.E. |"They couldn't hit an elephant at chrisw@skypoint.com | this distance" (last words of Gen.

.......................................| John Sedgwick, Spotsylvania
1864)
http://www.skypoint.com/~chrisw/ Received on Wed Jul 25 16:30:00 2007