Re: [PipingDesign] Fitting Class Rating to be installed on a Pressure Vessel

From: <Mawan>
Date: Tue Jan 22 2008 - 02:16:00 EST

Sajit,

Basically why they insisted suggesting us to use 6000# full coupling rather than 3000# full coupling was based on the original design of this vessel and other fittings previously there were rated at 6000#. Therefore, using 3000# will alter the design and require more effort to get recertification from third party (I bet you know what I meant)

With regard to attachment enclosed in my previous mail, I'm sorry for that. Next time I'll ask moderator to provide a link supposed I mail a subject to this address with file attachment.

Thanks,
Mawan Darmawan

Mawan,

What is the reasoning why your QA guy wants to have the 6000# coupling. Has it to do with the area replacement by reinforcement of an opening on the vessel. Have you considered a 3000# O-let fitting. This should provide more reinforcement area than a half coupling.

It may be a code para or a technicality that he must be basing it on. Why don't you ask him?