Re: Internal Phenolic Epoxy coating

From: <Mohammed>
Date: Wed Feb 06 2008 - 01:31:00 EST

I forget to mention that service is : SOUR CRUDE OIL

Internal Epoxy coating required to prevent the C.S. valve body from corrosion.

Regards
Alamgeer

> First of all, Why are utilizing valve with internal
> phenolic coating in crude oil service?
>
> --- alamgeer5798 <alamgeer5798@yahoo.com> wrote:
>
> > Material requirement for valve body is C.S. with
> > Internal Phenolic
> > Epoxy coating. But Manufacturing is supplying
> valve
> > body of S.S.
> > In this instance Internal Phenolic Epoxy coating
> > still required?
> > I believe internal coating is not required!
> > Anyone differ from this? please advice!
> >
> > The service is Crude Oil.
> >
> >
> >
> >
>
>
      