RE: Stress Reliving

From: <Chakraborty>
Date: Tue Feb 26 2008 - 01:51:00 EST

For CS pipe (A 106 Gr. B) in Sour service, PWHT is mandatory. It is a service requirement.

'Hope this helps.

Regards

Chakra
-----Original Message-----
From: sabirap [mailto:sabirap@yahoo.com] Sent: Tuesday, February 26, 2008 12:15 PM To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] Stress Reliving

Gents

How to find out whether PWHT and stress reliving is required for a line.

The Pipe spec is
6'', BE, SCH XS, SMLS, A106 GR. B SOUR SERVICE Thank you,

Regards,

Sabir

This Message was sent from Indian Oil Messaging Gateway. The information contained in this electronic message and any attachments to this message are intended for the exclusive use of the addressee(s) and may contain proprietary, confidential or privileged information. If you are not the intended recipient, you should not disseminate, distribute or copy this e-mail. Please notify the sender immediately and destroy all copies of this message and any attachments.

[Non-text portions of this message have been removed] Received on Tue Feb 26 01:51:00 2008

This archive was generated by hypermail 2.1.8 : Mon Oct 27 2008 - 20:24:15 EDT