Hi Shabbar,
You are right, stress factor, equation numbers, combined stress values are not matching with manual calculation.
Regards,
Hitesh
From: PipingDesign@yahoogroups.com [mailto:PipingDesign@yahoogroups.com]
On Behalf Of syed shabbar
Sent: January 5, 2009 11:21 AM
To: PipingDesign@yahoogroups.com
Subject: [PipingDesign] API 650, tenth edition, november 2003, appendix
P, P3
Dear all,
I have been using appendix p,p.3 of API 650 tenth edition november 2003 release. But during the course i have encountered a problem. The interpolations which are given in the solved example of the above mention appendix didnt match with the manual calculation i.e the some stress factors are not correctly interpolated. if some one encountered with the same problem then kindly let me know, or if i m wrong then plz do correct me.
regards
shabbar
[Non-text portions of this message have been removed]
[Non-text portions of this message have been removed]
Received on Mon Jan 05 16:02:00 2009